Technology |
Laser scanner, time-of-flight measurement |
---|---|
Detection mode |
Presence |
Max. detection range |
5.0 m × 5.0 m |
Uncovered zone |
5 - 25 cm (adjustable) |
Remission factor |
> 2 % |
Angular resolution |
0,3516 ° |
Min. detected object size (typ.) |
2.1 cm @ 3 m ; 3.5 cm @ 5 m (in proportion to object distance) |
Testbody |
700 mm × 300 mm × 200 mm (Testbody CA according to EN16005/DIN18650) |
Emission characteristics |
|
IR Laser |
Wavelength 905nm; max. output pulse power 75W (Class 1) |
Red visible Laser |
Wavelength 650nm; max. output CW power 3mW (Class 3R) |
Supply voltage |
10-35 V DC @ sensor side |
Power consumption |
< 5 W |
Peak current at power-on |
1.8 A (max. 80 ms @ 35 V) |
Response time typ |
20 ms; max. 80 ms (+ output activation delay) |
Output |
2 electronic relays (galvanic isolated - polarity free) |
Max. switching voltage |
35 V DC / 24 V AC |
Max. switching current |
80 mA (resistiv) |
Input |
2 optocouplers (galvanic isolated - polarity free) |
Max. contact voltage |
30 V DC (over-voltage protected) |
Voltage threshold |
Log. H: >8 V DC; Log. L: <3 V DC |
Dimensions |
125 mm (D) × 93 mm (W) × 70 mm (H) (Montagesockel + 14 mm) |
Material |
PC/ASA |
Colour |
Black or white |
Rotation angles on bracket |
-5 ° to +5 ° (lockable) |
Tilt angles on bracket |
-3 ° to +3 ° |
Protection degree |
IP65 |
Temperature range |
-30°C to +60°C if powered; -10°C to +60°C unpowered |
Humidity |
0-95% non-condensing |
Vibrations |
< 2 G |
Expected lifetime |
20 years |
Norm conformity |
EN 12978:2009; EN ISO 13849-1:2008 CAT2, Pl “d”; EN 60529:2001; IEC 60825-1:2007; EN 60950-1:2005; EN 61000-6-2:2005; EN 61000-6-3:2006; IEC 61496-1:2009; EN 61496-3:2008 ESPE Type 2; EN 62061:2005 SIL 2; EN 16005:2012 Chapter 4.6.8; DIN 18650-1:2010 Chapter 5.7.4; BS 7036-1:1996 Chapter 8.1 |
Specifications are subject to changes without prior notice – Measured in specific conditions.