Technology: |
LASER scanner, time-of-flight measurement |
---|---|
Detection mode: |
Presence |
Max. detection range: |
Max 5.5*5.5 m (4m@5%reflectivity) |
Opening angle: |
90° |
Angular resolution: |
0.23° |
Testbody: |
700 mm × 300 mm × 200 mm |
Emission characteristics: |
Wavelength 905 nm; max. output pulse power 25 W (CLA SS 1) |
Supply voltage: |
12 - 24 V DC ± 15 % |
Power consumptionx: |
≤ 2.3W; peak current: 1A |
Response time: |
Max. 50 ms (output activation delay) |
Output: |
1 electronic relay (galvanic isolation - polarity free) |
LED-signals: |
1 tri-colored LED: detection/output status |
Dimensions: |
124 mm (L) × 90 mm (H) × 50 mm (D) (without bracket ) |
Color: |
black |
Tilt angles: |
±3° ( With bracket ) |
Protection degree: |
IP66 (EN 60529) |
Temperature range: |
-30°C to +60°C if powered |
Humidity: |
0-95 % non-condensing |
Remission factor: |
> 2% |
Vibrations: |
< 2 G |
Norm conformity: |
IEC 60825-1; EN 60950-1; EN 61000-6-2; |
Specifications are subject to changes without prior notice – Measured in specific conditions.