Supply voltage: |
12 V - 30 V DC -5%/+10% (to be operated from SELV compatible power supplies only) |
---|---|
Power consumption: |
< 1.6 W |
Mounting height: |
1.8 m to 3 m |
Sensitivity of the test input: |
< 1 V : Log. L; > 10 V: Log. H (max. 30 V) |
Temperature range: |
-25 °C to +55 °C |
Degree of protection: |
IP54 |
Noise: |
< 70 dB |
Expected lifetime: |
20 years |
Norm conformity: |
EN 16005:2012; EN 12978:2009; EN IEC 62061:2005 SIL2; EN 61496-1:2012 ESPE Type 2; EN ISO 13849-1:2008 Pl «c» CAT.2 |
Detection mode: |
Presence |
Technology: |
Active infrared with background analysis |
Angle: |
From -4 ° to +4 ° (adjustable) |
Output: |
Solid-state-relay |
Hold time output signal: |
0.3 s to 1 s (not adjustable) |
Response time on test request: |
Typical: < 5 ms |
Specifications are subject to changes without prior notice – Measured in specific conditions.