Technology |
active infrared, microprocessor |
---|---|
Mounting height |
min. 0.2 m above the floor |
Distance between beams |
min. 0.3 m (crossed beams) |
Distance in relation to the door plane |
2 cm |
Minimum range |
1 m |
Maximum range |
5 m - for min. mounting height of 0.2 m; 10 m - for min. mounting height of 0.4 m |
Half-opening angle of the beam |
8° |
Detection mode |
presence (beam interruption) |
Output response time |
≤ 40 ms MICROCELL THREE |
Hold time |
300 ms |
Supply voltage |
12-24 V AC ±10% - 12-24 V DC –5/+30% MICROCELL THREE |
Current consumption |
< 100 mA |
Output |
1 or 2 relays (free potential contact) MICROCELL THREE |
Signal |
1 LED per barrier |
Temperature range |
–20°C to +55°C |
Degree of protection |
IP 65 (DIN 40050) |
Dimensions heads |
housing : 10 mm (built-in) x 12.4 mm (diameter); collar : diameter 15.6 mm |
Cable length |
5 m (10 m optional) |
Weight emitter - receiver |
0.140 Kg (5 m) / 0.270 kg (10 m) |
Material |
ABS |
Housing color |
blue transparent |
Specifications are subject to changes without prior notice – Measured in specific conditions.