Technology: |
inductive loop |
---|---|
Tuning: |
automatic |
Detection mode: |
presence or pulse |
Presence time: |
1 min to infinity |
Pulse time output: |
100 ms or 500 ms |
Inductance range: |
20 μH to 1000 μH |
Frequency range: |
20 kHz to 130 kHz |
Frequency steps: |
MATRIX-S: 4, MATRIX-D: 2x2 |
Sensitivity (ΔL/L): |
0.005% to 0.5% |
Reaction time: |
25 ms |
Power supply: |
MATRIX-S & -D 12-24: 12-24 V AC/DC +/-10% |
Mains frequency: |
48 to 62 Hz |
Power consumption: |
< 2.5 W |
Degree of protection: |
IP40 |
Temperature range: |
-30 °C to +70 °C (storage); -30 °C to +40 °C (operating) |
Output: |
2 relays (free potential change-over contact) |
LED indicators: |
green LED: power; red LED: loop status |
Protections: |
loop insulation transformer, zener diodes, gas discharge clamping |
Main connector: |
standard 11-pin round connector 86CP11 |
Dimensions: |
77 mm (H) x 40 mm (W) x 75 mm (D) |
Weight: |
< 200 g |
Specifications are subject to changes without prior notice – Measured in specific conditions.