Technology |
LASER scanner, time-of-flight measurement |
---|---|
Detection mode |
Presence ( EN 12453 Type E ) |
Max. detection range LZR®-I100 |
9.9 m × 9.9 m |
Max. detection range LZR®-I110 |
5 m × 5 m |
Remission factor |
> 2 % |
Angular resolution |
0,3516° |
Typ. min. object size |
2,1 cm @ 3 m / 3,5 cm @ 5 m / 7 cm @ 10 m (in proportion to object distance) |
Testbody |
700 mm × 300 mm × 200 mm (testbody A according to EN 12445) |
Emission characteristics |
|
IR LASER |
Wavelength 905 nm; max. output pulse power 75 W; Class 1 |
Red visible LASER |
Wavelength 650 nm; max. output CW power 3 mW; Class 3R |
Supply voltage |
10-35V DC @ sensor terminal |
Power consumption |
< 5 W |
Response time |
Typ. 20 ms; max. 80 ms |
Output |
2 electronic relays ( galvanic isolation - polarity free ) |
Max. switching voltage |
35V DC / 24V AC |
Max. switching current |
80 mA (resistive) |
LED-signals |
1 blue LED: power-on status |
Dimensions |
125 mm (L) × 93 mm (D) × 70 mm (H) ( mounting bracket + 14 mm ) |
Material |
PC/ASA |
Colour |
Black / White |
Rotation angles on bracket |
-5° to +5° ( lockable ) |
Tilt angles on bracket |
-3° to +3° |
Protection degree |
IP65 |
Temperature range |
-30 °C to +60 °C if powered |
Humidity |
0-95 % non-condensing |
Vibrations |
< 2 G |
Norm conformity |
EN 12453: 2000 chapter 5.1.1.6, chapter 5.5.1 Safety device E ; EN 12978: 2009 ; EN ISO 13849-1: 2008 Pl “d”/ CAT2 ; EN 60529: 2001 ; IEC 60825-1: 2007 ; EN 60950-1: 2005 ; EN 61000-6-2: 2005 ; EN 61000-6-3: 2006 ; IEC 61496-1: 2009 ; EN 61496-3: 2008 ESPE Type 2 ; EN 62061: 2005 SIL 2 ; DIN 18650-1: 2010 Chapter 5.7.4 |