| Technology: | laser scanner, time-of-flight measurement (4 laser curtains) | 
|---|---|
| Detection mode: | motion and presence | 
| Max. detection range: | 9.9 m x 9.9 m | 
| Remission factor: | > 2 % | 
| Angular resolution: | 0,3516 ° | 
| Emission characteristics | IR laser: wavelength 905 nm; max. output pulse power 75 W (CLASS 1) | 
| Supply voltage: | 10-35 V DC @ sensor side | 
| Power consumption: | < 5 W | 
| Peak current at power-on: | 1.8 A (max. 80 ms @ 35 V) | 
| Cable length: | 5 m (standard), max. : 10 m | 
| Response time |   | 
| Output: | 2 electronic relays (galvanic isolated - polarity free) | 
| Max. switching voltage: | 35 V DC / 24 V AC | 
| Max. switching current: | 80 mA (resistive) | 
| Switching time: | tON=5 ms; tOFF=5 ms | 
| Output resistance: | typ 30 Ω | 
| Voltage drop on output: | < 0.7 V @ 20 mA< 10 μA | 
| Leakage current: | < 10 μA | 
| Input: | 1 optocoupler (galvanic isolated - polarity free) | 
| Max. contact voltage: | 30 V DC (over-voltage protected) | 
| Voltage threshold: | Log. H: >8 V DC; Log. L: <3 V DC | 
| LED-signal: | 1 blue LED: power-on status | 
| Dimensions: | 125 mm (D) x 93 mm (W) x 70 mm (H) (with mounting bracket + 14 mm) | 
| Material: | PC/ASA | 
| Colour: | black | 
| Mounting angles on bracket: | -45 °, 0 °, 45 ° | 
| Rotation angles on bracket: | -5 ° to +5 ° (lockable) | 
| Tilt angles on bracket: | -3 ° to +3 ° | 
| Protection degree: | IP65 | 
| Temperature range: | -30 °C to +60 °C if powered; -10 °C to +60 °C unpowered | 
Specifications are subject to changes without prior notice – Measured in specific conditions.