Technology: |
laser scanner, time-of-flight measurement (4 laser curtains) |
---|---|
Detection mode: |
motion and presence |
Max. detection range: |
9.9 m x 9.9 m |
Remission factor: |
> 2 % |
Angular resolution: |
0,3516 ° |
Emission characteristics |
IR laser: wavelength 905 nm; max. output pulse power 75 W (CLASS 1) |
Supply voltage: |
10-35 V DC @ sensor side |
Power consumption: |
< 5 W |
Peak current at power-on: |
1.8 A (max. 80 ms @ 35 V) |
Cable length: |
5 m (standard), max. : 10 m |
Response time |
|
Output: |
2 electronic relays (galvanic isolated - polarity free) |
Max. switching voltage: |
35 V DC / 24 V AC |
Max. switching current: |
80 mA (resistive) |
Switching time: |
tON=5 ms; tOFF=5 ms |
Output resistance: |
typ 30 Ω |
Voltage drop on output: |
< 0.7 V @ 20 mA< 10 μA |
Leakage current: |
< 10 μA |
Input: |
1 optocoupler (galvanic isolated - polarity free) |
Max. contact voltage: |
30 V DC (over-voltage protected) |
Voltage threshold: |
Log. H: >8 V DC; Log. L: <3 V DC |
LED-signal: |
1 blue LED: power-on status |
Dimensions: |
125 mm (D) x 93 mm (W) x 70 mm (H) (with mounting bracket + 14 mm) |
Material: |
PC/ASA |
Colour: |
black |
Mounting angles on bracket: |
-45 °, 0 °, 45 ° |
Rotation angles on bracket: |
-5 ° to +5 ° (lockable) |
Tilt angles on bracket: |
-3 ° to +3 ° |
Protection degree: |
IP65 |
Temperature range: |
-30 °C to +60 °C if powered; -10 °C to +60 °C unpowered |
Specifications are subject to changes without prior notice – Measured in specific conditions.