i-access-controli-access-controli-artwork-protectioni-automated-windowsi-barrier-freei-barriersi-bus-doorsfooi-crosswalki-emergency-calli-escalatorsi-flammablei-gatesi-guidancei-high-performance@1x-100Asset 2innovation_iconi-knowing-acti-loading-docki-low-energy-doorfooi-parkingi-pass-through-windowi-people-countingi-perimeter-protectioni-plateform-screen-doori-request-to-exiti-revolving-doori-sectional-doorAsset 3i-sliding-doorsi-swinging-doorsi-toll-gatesGroup 15i-train-doorsi-vehicle-classificationi-warehousingi-low-energy-doori-request-to-exitArtboardfacebookinstagramlinkedintwitterwechatYouku-iconyoutubeempowermentAsset 1Asset 2innovationbrochureGroup 11productpassionproductsrespectAsset 3Combined ShapeteamworkArtboard@2xGroup 11whitepaperwiring-diagramsairporthospitalsindustrylogisticsretailco2flexible rapidespiralsectionnelspiral rapideenergywalletArtboardarrowarrow-redux-bigarrow-redux-toparrow-redux-toparrow-reduxarrowArtboard@2xcountrydownloadeyefile2filtergridhamburgerlanguagelistnopdfphoneplusresetsearchsubscribevideoyesArtboard@2x

We've detected you are coming from another region. Please choose one of the options:

Please select your preferred market and language

Go
Or

Table of specifications

Technology:

LASER scanner, time-of-flight measurement

Detection mode:

Presence

Max. detection range:

4m ( diagonal ) with reflectivity of 5%
5m ( diagonal ) with reflectivity of 8%

Opening Angle:

90°

Angula resolution:

0.23° ( 400 spots within 90°)

Testbody:

700 mm × 300 mm × 200 mm (testbody CA) according to EN 16005 & DIN 18650, <4m; 50mm cylinder CB testbody according DIN18650 <3.5m height

Emission characteristics:

Wavelength 905 nm; max. output pulse power 25 W (Class 1)

IR LASER:

Wavelength 650 nm; max. output CW power 3 mW (CLASS 3R) visible spots

Supply voltage:

12-24V DC ± 15%

Power consumption:

≤ 2.3 W

Response time:

max. 90 ms

Output:

1 optocoupler ( galvanic isolation - polarity free )
Max. switching voltage: 42V AC/ 60V DC
Max. switching current: 100 mA
1 Relay ( free of potential change-over contact )
Max. contact voltage: 60V AC / 125V DC
Max. contact current: 1.0A ( resistive )
Max. switching power: 30W ( DC ) / 60VA ( AC )

LED-signals:

1 bi-colored LED: detection/ output status

Dimensions:

178 mm (L) × 85 mm (H) × 53 mm (D)

Material-Colour:

PC/ABS - Black

Tilt angles:

0° ~ +5°

Protection degree:

IP54 (EN 60529)

Temperature range:

-30°C to +60°C if powered

Humidity:

0-95% non-condensing

Vibrations:

< 2 G

Norm conformity:

EN 12978; EN ISO 13849-1 Pl “d”/ CAT2; IEC 60825-1; EN 60950-1; EN 61000-6-2; EN
61000-6-3; EN 62061 SIL 2; DIN 18650-1 Chapter 5.7.4 ( testbody CA & testbody CB );
EN16005 Chapter 4.6.8 ( testbody CA )
Specifications

Specifications are subject to changes without prior notice – Measured in specific conditions.

We have full ranges of products for your needs ! See all our products

Subscribe to our newsletter