i-access-controli-access-controli-artwork-protectioni-automated-windowsi-barrier-freei-barriersi-bus-doorsfooi-crosswalki-emergency-calli-escalatorsi-flammablei-gatesi-guidancei-high-performance@1x-100Asset 2innovation_iconi-knowing-acti-loading-docki-low-energy-doorfooi-parkingi-pass-through-windowi-people-countingi-perimeter-protectioni-plateform-screen-doori-request-to-exiti-revolving-doori-sectional-doorAsset 3i-sliding-doorsi-swinging-doorsi-toll-gatesGroup 15i-train-doorsi-vehicle-classificationi-warehousingi-low-energy-doori-request-to-exitairporthospitalsindustrylogisticsretailArtboardempowermentAsset 1Asset 2innovationbrochureGroup 11productpassionproductsrespectAsset 3Combined ShapeteamworkArtboard@2xGroup 11whitepaperwiring-diagramsfacebookinstagramlinkedintwitterwechatYouku-iconyoutubeco2flexible rapidespiralsectionnelspiral rapideenergywalletArtboardarrowarrow-redux-bigarrow-redux-toparrow-redux-toparrow-reduxarrowArtboard@2xcountrydownloadeyefile2filtergridhamburgerlanguagelistnopdfphoneplusresetsearchsubscribevideoyesArtboard@2x

We've detected you are coming from another region. Please choose one of the options:

Please select your preferred market and language

Go
Or

Technical specifications

Supply voltage

12 V - 24 V AC +/-10% ; 12 V - 30 V DC +/-10% (to be operated from SELV compatible power supplies only)

Power consumption

< 2.5 W

Mounting height

2 m to 3.5 m (local regulations may have an impact on the acceptable mounting height)

Temperature range

-25°C to +55°C; 0-95% relative humidity, non condensing

Degree of protection

IP54

Noise

< 70 dB

Expected lifetime

20 years

Detection mode

Presence

Typical response time

< 200 ms (max. 500 ms)

Technology

Active infrared with background analysis

Spot

5 cm x 5 cm (typ)

Number of spots

max. 24 per curtain

Number of curtains

IXIO-ST: 2
IXIO-ST SIDE SCREEN: 1

Output

IXIO-ST
Solid-state-relay (potential and polarity free)
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC
Holdtime: 0.3 to 1 s

IXIO-SP
Pulse polarity: negative
Level: standby: pulse from V to ground
Level: detection: V supply
Topology: op-collector with 4.7 K to 3.3 V
Max. sink current: 25 mA with external 1 K to 24 V
Optional: Solid-state-relay
(potential and polarity free)
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC

Test input:

IXIO-ST
Sensitivity: Low: < 1 V; High: > 10 V (max. 30 V)
Response time on test request: typical: < 5 ms IXIO-SP Pulse polarity: positive or negative (adjustable) Impedance: Positive pulse: 2 K to ground Negative pulse: 470 R to + sensor power supply Pulse voltage: 6 V to 30 V Pulse duration: 4 μs to 500 μs Duty cycle: max. 50%

Norm conformity:

EN 12978, EN ISO 13849-1:2008 PL «c» CAT. 2
(under the condition that the door control system monitors the sensor at least once per door cycle)
IEC 61496-1:2012 ESPE Type 2
EN 16005:2012 Chapter 4.6.8; DIN 18650-1:2010 Chapter 5.7.4; BS 7036-1:1996 Chapter 8.1

Specifications are subject to changes without prior notice – Measured in specific conditions.

need more information Contact us

Subscribe to our newsletter

Learn more