i-access-controli-access-controli-artwork-protectioni-automated-windowsi-barrier-freei-barriersi-bus-doorsfooi-crosswalki-emergency-calli-escalatorsi-flammablei-gatesi-guidancei-high-performance@1x-100Asset 2innovation_iconi-knowing-acti-loading-docki-low-energy-doorfooi-parkingi-pass-through-windowi-people-countingi-perimeter-protectioni-plateform-screen-doori-request-to-exiti-revolving-doori-sectional-doorAsset 3i-sliding-doorsi-swinging-doorsi-toll-gatesGroup 15i-train-doorsi-vehicle-classificationi-warehousingi-low-energy-doori-request-to-exitairporthospitalsindustrylogisticsretailArtboardempowermentAsset 1Asset 2innovationbrochureGroup 11productpassionproductsrespectAsset 3Combined ShapeteamworkArtboard@2xGroup 11whitepaperwiring-diagramsfacebookinstagramlinkedintwitterwechatYouku-iconyoutubeco2flexible rapidespiralsectionnelspiral rapideenergywalletArtboardarrowarrow-redux-bigarrow-redux-toparrow-redux-toparrow-reduxarrowArtboard@2xcountrydownloadeyefile2filtergridhamburgerlanguagelistnopdfphoneplusresetsearchsubscribevideoyesArtboard@2x

We've detected you are coming from another region. Please choose one of the options:

Please select your preferred market and language

Go
Or

Table of specifications

SUPPLY VOLTAGE

12 V - 24 V AC +/-10% (50 - 60 Hz) ; 12 V - 30 V DC +/-10%

POWER CONSUMPTION

< 2.5 W

MOUNTING HEIGHT

2 m to 3.5 m

TEMPERATURE RANGE

-25°C to +55°C; 0-95% relative humidity, non condensing

DEGREE OF PROTECTION

IP54 (IEC/EN 60529)

NOISE

< 70 dB

DETECTION MODE

Motion
Min. detection speed: 5 cm/s

Presence
Typical response time: < 200 ms (max. 500 ms)

TECHNOLOGY

Microwave doppler radar
Transmitter frequency: 24.150 GHz
Transmitter radiated power: < 20 dBm EIRP Transmitter power density: < 5 mW/cm2

Active infrared with background analysis
Spot: 5 cm x 5 cm (typ)
Number of spots: max. 24 per curtain
Number of curtains: 2

OUTPUT

IXIO-DT1/-DP1
Solid-state-relay (potential and polarity free)
Max. contact current: 100 mA
Max. contact voltage: 42 V DC/ 30 V AC

IXIO-DT3/DP3
Solid-state-relay (potential and polarity free)
Max. contact current: 100 mA
Max. contact voltage: 42 V DC/ 30 V AC
In switching mode: NO/NC
In frequency mode: pulsed signal
(f= 100 Hz +/- 10%)
In inverted frequency mode: pulsed signal
in detection (f = 2.5 Hz)
Galvanically isolated current source
No detection: current source ON
Open circuit voltage: 6.5 V
Output voltage available at 10 mA: 3 V min.
Typical load: up to 3 optocouplers in series
Detection: current source OFF
Open-circuit remained voltage: < 500 mV

IXIO-DT3/-DT1
Solid-state-relay (potential and polarity free)
Max. contact current: 100 mA
Max. contact voltage: 42 V DC/ 30 V AC
Holdtime: 0.3 to 1 s

INPUT

IXIO-DP3/-DP1
Pulse polarity: positive or negative (adjustable)
Impedance:
- Positive pulse: 2 K to ground
- Negative pulse: 470 R to + sensor power supply
Pulse voltage: 6 V to 30 V
Pulse duration: 4 μs to 500 μs
Duty cycle: max. 50%

TEST INPUT

IXIO-DT3/-DT1
Sensitivity: Low: < 1 V; High: > 10 V (max. 30 V) Response time on test request: typical: < 5 ms

CONFORMITY

This product conforms to all applicable European Union legislation. Please refer to the Declaration of Conformity for further information.

Specifications are subject to changes without prior notice – Measured in specific conditions.

need more information Contact us

Subscribe to our newsletter

Learn more